Model:ParFlow: Difference between revisions
From CSDMS
m (removed old questionnaire information. Replaced with form) |
No edit summary |
||
Line 3: | Line 3: | ||
|Last name=Maxwell | |Last name=Maxwell | ||
|Type of contact=Project manager | |Type of contact=Project manager | ||
|Institute / Organization=International Groundwater Modeling Center, Colorado School of Mines | |Institute / Organization=International Groundwater Modeling Center, Colorado School of Mines | ||
|Postal address 1=1500 Illinois St | |Postal address 1=1500 Illinois St | ||
|Postal address 2=Colorado School of Mines | |Postal address 2=Colorado School of Mines | ||
Line 34: | Line 34: | ||
|Start year development=1994 | |Start year development=1994 | ||
|Does model development still take place?=Yes | |Does model development still take place?=Yes | ||
|Model availability=As code | |Model availability=As code | ||
|Source code availability=Through | |Source code availability=Through web repository | ||
|Source web address=http://inside.mines.edu/~rmaxwell/maxwell_software.shtml | |Source web address=http://inside.mines.edu/~rmaxwell/maxwell_software.shtml | ||
|Program license type=LGPL | |Program license type=LGPL | ||
Line 41: | Line 41: | ||
|CCA component=No but possible | |CCA component=No but possible | ||
|IRF interface=No but possible | |IRF interface=No but possible | ||
|Memory requirements=depends on problem size | |Memory requirements=depends on problem size | ||
|Typical run time=depends on problem size | |Typical run time=depends on problem size | ||
}} | }} | ||
{{Input - Output description | {{Input - Output description | ||
|Describe input parameters=TCL script, many physical and numerical parameters needed. | |Describe input parameters=TCL script, many physical and numerical parameters needed. | ||
|Input format=ASCII, Binary | |Input format=ASCII, Binary | ||
|Describe output parameters=Many: pressure, saturation, temperature, energy fluxes, flow, etc. | |Describe output parameters=Many: pressure, saturation, temperature, energy fluxes, flow, etc. | ||
|Output format=ASCII, Binary | |Output format=ASCII, Binary | ||
|Pre-processing software needed?=No | |Pre-processing software needed?=No | ||
|Post-processing software needed?=Yes | |Post-processing software needed?=Yes | ||
|Describe post-processing software=ParFlow comes with a robust, integrated toolkit (pftools) that provides a wide range of postprocessing options. | |Describe post-processing software=ParFlow comes with a robust, integrated toolkit (pftools) that provides a wide range of postprocessing options. | ||
|Visualization software needed?=Yes | |Visualization software needed?=Yes | ||
|If above answer is yes=Matlab | |If above answer is yes=Matlab | ||
Line 71: | Line 71: | ||
}} | }} | ||
{{Model testing | {{Model testing | ||
|Describe available calibration data sets=ParFlow contains a directory of test cases that may be automated as a check of the code. | |Describe available calibration data sets=ParFlow contains a directory of test cases that may be automated as a check of the code. | ||
|Describe available test data sets=ParFlow contains a directory of test cases that may be automated as a check of the code. | |Describe available test data sets=ParFlow contains a directory of test cases that may be automated as a check of the code. | ||
|Describe ideal data for testing=-- | |Describe ideal data for testing=-- | ||
}} | }} | ||
{{Users groups model | {{Users groups model | ||
|Do you have current or future plans for collaborating with other researchers?=Yes, many already in progress. | |Do you have current or future plans for collaborating with other researchers?=Yes, many already in progress. | ||
}} | }} | ||
{{Documentation model | {{Documentation model |
Revision as of 16:52, 28 April 2010
Contact
Name | Reed Maxwell |
Type of contact | Project manager |
Institute / Organization | International Groundwater Modeling Center, Colorado School of Mines |
Postal address 1 | 1500 Illinois St |
Postal address 2 | Colorado School of Mines |
Town / City | Golden |
Postal code | 80401 |
State | Colorado |
Country | USA"USA" is not in the list (Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, ...) of allowed values for the "Country" property. |
Email address | rmaxwell@mines.edu |
Phone | 303-384-2456 |
Fax |
Name | Steven Smith |
Type of contact | Model developer |
Institute / Organization | |
Postal address 1 | |
Postal address 2 | |
Town / City | |
Postal code | |
State | |
Country | |
Email address | |
Phone | |
Fax |
Name | Stefan Kollet |
Type of contact | Technical contact |
Institute / Organization | |
Postal address 1 | |
Postal address 2 | |
Town / City | |
Postal code | |
State | |
Country | |
Email address | |
Phone | |
Fax |
ParFlow
Metadata
Summary
Technical specs
In/Output
Process
Testing
Other
IntroductionHistoryPapersIssuesHelpInput FilesOutput FilesDownloadhttp://inside.mines.edu/~rmaxwell/maxwell_software.shtml Source |